29/10/2026
Give each person their own code on a Trilogy T2. Three steps from Alarm Lock's programming guide.
Before you start: change the factory master code first. User codes use the same number of digits as the master code.
1. Enter the master code (or the associated manager code).
2. Press AL, the 2-digit user location (bank, then row, like 01), then AL.
3. Enter the new user code. Wait for 6 beeps, then about 5 seconds for it to re-lock.
Example: master code, AL, 0 1, AL, 2 2 2 2 2 stores code 22222 at location 01.
Beeps: 6 means accepted, 5 means invalid code, two sets of 5 means a programming error.
Duplicate codes aren't allowed. Manager codes go in locations ending in 0 and can only be added with the master code.
Alarm Lock Trilogy keypad locks: https://www.keylessaccesslocks.com/alarm-lock-trilogy/?utm_source=facebook&utm_medium=video&utm_campaign=howto_t2_user
Trilogy T2 DL2700IC with SFIC core prep: https://bandhdepot.com/dl2700ic-us26d-alarm-lock-access-control.html?utm_source=facebook&utm_medium=video&utm_campaign=howto_t2_user